| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/27/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/23/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL ROOF SOUTH (ABOVE) SKY LIGHT AND SOUTH END OF PORCH 2) PATIO ROOF LEDGERS NOT CLIPPED NORTH LEDGER |
|
| 12/21/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEAR OSB NOT NAILED BEHIND MASTER SINK PLUMBING 2) CUT VIEW HOLES IN FRONT COLUMN OSB 3) STRAP NON-CABIN TIED TOP PLATES AT ENTRY ANGLED WALLS 4) PATIO ROOF LEDGERS NOT CLIPPED |
|
| 12/20/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FRONT SHEARWALL NOT NAILED PROPERLY WHERE SHINNERS 2) NO ACCESS TO ROOF. PROVIDE SECURE LADDER |
|
| 12/17/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : There is no plan or job inspection card on site.| 925* 1) NO PLANS/PERMIT ON SITE |
|
| 12/16/2004 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | CANCELLED PER ROB - STEVE NOTIFIED | |
| 12/16/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ADDRESS NOT FOUND ON HOUSE 2) NO PLAN OR PERMIT FOUND |
|
| 12/15/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED H2.5'S REAR PORCH LEDGER (DETAIL 8 PAGER 5) 2) ONE ROW OF NAILS MISSING INTERIOR DEN SHEARWALL 3) NO ACCESS 4) NUMBEROUS SHINERS FRONT SHEARWALL 5) SOLE PLATE FRONT SHEAR WALL NOT BOLTED 6) NEED HOLDOWNS FRONT WALL |