Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/27/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/23/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MOST STRAPS INSTALLED ON NORTH PATIO LEDGER, ARE NOT NAILED INTO STRUCTURAL MEMBERS AT THE TOP END. NEED TO HIT TRUSSES OR LAG |
|
| 12/21/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 1 CIRCUIT NOT NAILED AT WALL ON PORCH 2) SECURE CHIMNEY CAHSE AT ROOF 3) PATIO COLUMNS MISSING WASHERS AND NUTS 4) PATIO ROOF LEDGERS NOT CLIPPED 5) STRAP NON-CABIN TIED TOP PLATE AT ENTRY AREA ANGLED WALLS |
|
| 12/17/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : There is no plan or job inspection card on site.| 925* 1) NO PLANS/PERMIT ON SITE 2) PROVIDE PROOF OF PLUMBING APPROVAL |