Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/08/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 03/07/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* FLASHINGS REQUIRED AT ROOF PENETRATIONS CHINA BOWL CAPS REQUIRED USE CLEANOUT PLUGS DESIGNED TO ACCEPT SCREW |
|
| 03/06/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE LISTING FOR BUILT IN BYPASS FEATURE FOR PRESSURE REDUCER AT WATER SERVICE OR PROVIDE EXPANSION TANKS AT WATER HEATERS. 2. PROVIDE LONG RADIUS DRAINAGE FITTING FOR SINK AIR ADMITTANCE VALVE BELOW FLOOD RIM OF FIXTURE. 3. PROVIDE PERMANENT SIGNAGE IN ELECTRICAL PANELS FOR PLASTIC WATER PIPING IN BUILDING. |