Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/02/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* 1) SOIL WATER TEST IS OK. 2) OK TO BACKFILL TRENCH. 3) NOTE: BLDG DRAIN IS STUBBED OUT @ TWO WAY C. O ONLY | |
| 02/01/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHALL PROVIDE L-SWEEPS FOR WASHER DRAINS. 2) SHALL EXTEND 2" TRAP ARM AND PROVIDE 2" P-TRAP @ TUB FOR UNIT #2. 3) RE TEST THE SYSTEM |
|
| 01/26/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY FOR INSPECTION. 2) SHALL EXPOSE ENTRIE UNDERGROUND PLBG SYSTEM AND PROVIDE A WATER TEST WITH MIN 10' OF HEAD |