Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/10/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 02/08/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RECALL WHEN STUCCO MESH IS COMPLETED 2) REAR PORCH MUST BE FASTENED 6" ON CENTER TOP PLATES |
|
| 02/07/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TO BE APPROVED WHEN STUCCO MESH IS COMPLETED BACK PORCH |
|
| 02/04/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FLUSH NAIL GARAGE SHEAR 2) PROVIDE STUDS 16" ON CENTER KITCHEN CABINET WALLS 3) FASTEN MESH 6" ON CENTER AT TOP PLATE AT PORCH (REAR) 4) NAIL PROTECT GARAGE DOOR TOP PLATE NORTH 5) MICROWAVE OUTLET MUST TERMINATE IN BOX 6) CABLE WIRE BY MAIN SERVICE EXPOSED 7) PROVIDE CLEARANCE AT PEX LINE FROM CANS IN KITCHEN 8) NAIL PROTECT BATH 2" VTRS 9) GROUND FOR TEMP POWER ? |
|
| 02/02/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |