Permit: T04CM04751

Parcel: 108192180


Addresses:

4490 N 1ST AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T04CM04751

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/20/2005 PLUMBING - FINAL Approved IVRS - Inspection :* PLUMBING FINAL OK OK FOR C OF O PENDING ANY OTHER INSPECTION
01/19/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 1) A HAND SINK MAY NOT BE INDIRECTLY WASTED 2) INDIRECT WASTE PIPING EXCEEDING FIFTEEN FEET REQUIRE A TRAP AND A VENT. 3) USE DRAINAGE FITTINGS ON CONNECTIONS
01/14/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
01/13/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*NOT READY
01/12/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) OK TO COVER DEMO'D FLOOR SINKS
2) FINAL NOT READY