Permit: T04CM04749

Parcel: 137055220

Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T04CM04749

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Not ready for Inspection

Date Description Inspector Results Comments
01/31/2005 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
01/31/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
01/28/2005 PLUMBING - ROUGH, SOIL Cancelled
01/14/2005 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO APPROVED PLAN ON SITE
2) NO ISOMETRIC DRAWINGS
3) THE UNAPPROVED PLAN SHOWS 2" FOR FLOOR SINKS TYING INTO A 4" EXISTING. THE EXISTING OS A 2" NOT 4".
4) THE WATER HEAD TEST FOR ALL THE 2" DWV TO FLOOR DRAINS, OVERHEAD (ABOVE CEILING) VENTS AND VENT STACKS IN WALLS IS OK BUT...
YOU MAY NOT COVER PIPE IN SOIL UNTIL PAPER PLANS ARE ON SITE AND INSPECTION APPROVED.