Inspection History Details
Inspection Status: Denied
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/04/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* COMPLY WITH LAST INSPECTION |
|
| 08/02/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* AFTER HOURS INSPECTION PER S. LONG 1) PARTIAL APPROVAL BLDG FINAL ONLY/PENDING SEWER REVISION AND CERTS 2) ALL OTHER FINAL APPROVED |
|
| 08/02/2005 | BUILDING - FINAL | Partial Approval | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH PREVIOUS INSPECTION |
|
| 07/31/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL KNOCKOUTS MAIN SERVICE/LABEL NON-METALIC PLUMBING 2) EXTERIOR GFCI OUTLETS DO NOT RESET 3) ANTI-SIPHON ALL HOSE BIBS 4) LOWER CLEANOUTS TO GRADE 5) THRESHOLD GREAT ROOM DOOR 6) MISSING CAN COVER LAUNDRY ROOM/HALLWAY 7) OPEN GROUND PANTRY OUTLET 8) SUBMIT REVISION MAIN SEWER CHANGE 9) SECURE DISHWASHER HOSE TO HIGHEST POINT 10) MISSING COVER PLATE DISPOSAL 11) MISSING FIXTURE EXTERIOR OPEN DECK 12) PROVIDE SAVE ACCES TO ROOF/AC NOT CONNECTED 13) COAT ROOF OPEN DECK 14) EXPOSE CONNECTION FOR HCS |
|
| 07/29/2005 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER PAPERWORK TURNED IN BY INSPECTOR R. FREIDINGER 2) ALL PIPING OK EXCEPT CONNECTION 3) ABS TO PVC USE GREEN GLUE |