Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/13/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 07/11/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRESTOP TUB SHOES TO 2ND FLOOR 2) INSULATE BEHIND TUB WALLS 3) 3" CLEARANCE NEEDED AT HALLWAY CANS FROM DUCT WORK 4) PEX LEAK HALLWAY 5) STUCCO MESH PARTIAL APPROVAL SEAL PENETRATIONS 6) REMOVE INSULATION BEHIND PLUMBING LINES 7) 3" CLEARANCE NEEDED FROM ALL CANS 8) CHECK ALL FIRE BLOCKS 9) NO ENGINEERED LETTER FOR ITEMS 5 AND 7 10) RECALL ROOF NAILING 11) STOPPED INSPECTION AT 1ST FLOOR |
|
| 07/07/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 06/30/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) MOVE SMOKE DETECTOR, IN WEST BEDROOM TO CLOSE TO VERT WALL OF DROP, TO PUT ON COVER 2) LEAK IN 2ND FLOOR FLOOR WASTE LINE (HALL WAY) AND HORIZONTAL VENT FOR KITCHEN 3) CUT IN T/CHORD OF TJI BEDROOM WEST 4) REMOVE DIAMETER FROM UNDER COUNTER AT PENINSULA 5) DBL LIVING BEAM, NEED NAIL PATERN FOR JOINING PLYS TOGETHER LOAD HANGING OFF ONE SIDE 6) BANG PLATES AT ROMEX EAST SLIDING DOOR AREA 7) LPI IN LIVING ROOM-PLAN CALLS FOR 11-7/8", YOU HAVE 9'-1/2" DEPTH 8) BANG PLATE AND T/PLATE LIVING ROOM WEST DOOR 9) NEED H20 WORKING PRESSURE 10) BANG PLATE, LAU VENT T/PLATE AND TOILET 18" TO CENTER 11) NEED H20 IN TUBS 12) F/BLK FURRED AIR DUCT 1ST AND 2ND FLOOR 13) CHECK ALL NAILING O.S.B. SHEARWALLS INTERIOR, SOME HORIZONTAL JOINTS NOT NAILED 6'-12" ON CENTER 14) OK TO COVER SOIL PIPE-DAMAGED PIPING REPAIRED 15) ROOF NAIL NOT APPROVED |
|
| 06/15/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 06/13/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |