Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/15/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 04/14/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 1, 8, 11, AND 12 FROM 4/12/05 NOT COMPLETE |
|
| 04/12/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) STUCCO LATH NOT COMPLETE AT GARAGE FRONT AND PATIO 2) W/H T & P LINE BEHIND STUCCO-MOVE 3) ANCHOR BOLTS MISSING AND LOOSE 4) CONNECT SHEAR WALL WITH 12 A35 CLIPS PER S-2 5) DUCT BOOT NOT IN L/R 6) PLUMBERS METAL TAPE NOT ALLOWED TO SUPPORT D.W.V. 7) A7H HANGERS NOT NAILED 8) TUB NOT VENTED ABOVE DRAIN CENTER LINE 9) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE 10) SOME INCORRECT HANGERS INSTALLED USE THA 218-2 AND LUS26-2 11) PROVIDE 1" CLEARANCE AT WATER HEATER VENT (ROOF) 12) FLOOR SHEATHING LOOSE 13) NAIL 2ND FLOOR PER PLAN 14) FIRE STOP GARAGE/BEDROOM WALL 15) STOPPED INSPECTION-TO MANY ITEMS |