Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM04715
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/03/2005 | FRAMING | Approved | IVRS - Inspection :* | |
02/01/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OVERSPANS AT HALL BATH SHEAR TRANSFER WALL 2) SEE INSPECTION DATED 1/21/05 3) SEAL MOISTURE BARRIER PENETRATIONS FROM INSIDE 4) DWV'S AND WATER LINES TEST PASSED 5) REPLACE BLOWN CRIPPLE AT FRONT BAY WINDOW AND NAIL PROTECT ELECTRIC |
|
01/21/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FRAMING WILL BE APPROVED WHEN ALL TRADES ARE COMPLETE 2) LATH SEAL ALL PENETRATIONS, GABLE AREA NOT DONE, WIRE MESH NOT ALLOWED TO TOUCH COPPER, DISSIMILAR METALS 3) FIRE BLOCK AT HOOD VENT 4) SECURE 4 GANG BOX AT ENTRY 5) ELECTRIC BOX HANGIN IN DEN 6) SECURE WATER LINE AT MASTER BATH 7) NAIL PROTECT ELECTRIC AT FRONT BEDROOM TOP PLATE |