Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM04683
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/07/2005 | FRAMING | Approved | IVRS - Inspection :* | |
03/04/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH NAILING PATTER 12/SD-4 AND 11/SD-4 2) NO WATER-DWV SYSTEM 3) SECURE ALL 90'S VENTS THROUGH ROOF |
|
02/28/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK ALL REGISTERS-3 SIDES 2) BACKING MISSING UPSTAIRS TUB 3) MISSING NAILS AT HANGERS AT GIRDER TRUSSES 4) FIREBLOCK STAIRWELL 5) COMPLETE MESH S.W. CORNER 2ND FLOOR 6) NO WATER DWV SYSTEM 7) COMPLETE DRAIN IN GARAGE WEST WALL 8) SECURE ALL WASTE 90'S THROUGH ROOF AND 1ST FLOOR 9) NAIL PROTECT VENT DOWNSTAIRS DRAIN BOTTOM PLATE (BATH) 10) FIRE BLOCK OVER KNOTCH STAIRWELL KITCHEN WALL 11) INSTALL RED HEAD GARAGE EAST WALL 12) COMPLY WITH DETAILS 11/SD-4 AND 12/SD-4 13) MISSING H.25'S S.E. CORNER |
|
02/25/2005 | FRAMING | Cancelled | IVRS - RI canceled |