Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04CM04673

Parcel: 140376340


Addresses:

6999 S GOSHAWK DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/01/2005 FRAMING Approved IVRS - Inspection :*
03/31/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HTT 16 HOLDOWN NOT INSTALLED
2) RED HEAD AB'S LOOSE
3) BLOCK ? HAND RAIL
4) LVL NOT NAILED
5) NAIL PROTECT WIRES S/E-BR 1 1/4" AND HALL BATH
6) BLOCK NON T AND G FLOOR S.W. BR
7) LAUNDRY MUST EXHAUST OUT OF ATTIC AND CANNOT HAVE SCREEN "T" CAP
8) SECURE KITCHEN WALL TOP PLATE
9) OK TO INSULATE. DO NOT COVER RED HEADS AND HD'S