Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM04666
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/13/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
01/10/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* OK TO STUCCO LATHE |
|
01/07/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OK TO DRY IN ROOF, DON'T LOAD UNTIL TRUSSES FIXED 2) NEED SHIM ON GABLE END TRUSS EAST BEARING PT. 3) NAIL P.A. AT GARAGE FRONT 4) TWO TRUSSES NEED REPAIR (A130 A03/ TRUSS #) |
|
01/04/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CABLES NOT TENSIONED 2) NAIL PROTECT PLUMBING 3) CLIPS AT BACK PATIO MISSING NAILS 4) OVER SPAN GARAGE EAST WALL 5) CHECK ENTIRE HOUSE H2.5'S MISSING NAILS 6) COMPLY WITH DETAIL 7/DT1, 3/DT1 7) A03 TRUSS REQUIRES ENGINEER REPAIR 8) CHECK TRUSS BRACING 9) STOPPED INSPECTION |