Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04CM04666

Parcel: 136100570

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T04CM04666

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
01/13/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/10/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
OK TO STUCCO LATHE
01/07/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO DRY IN ROOF, DON'T LOAD UNTIL TRUSSES FIXED
2) NEED SHIM ON GABLE END TRUSS EAST BEARING PT.
3) NAIL P.A. AT GARAGE FRONT
4) TWO TRUSSES NEED REPAIR (A130 A03/ TRUSS #)
01/04/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CABLES NOT TENSIONED
2) NAIL PROTECT PLUMBING
3) CLIPS AT BACK PATIO MISSING NAILS
4) OVER SPAN GARAGE EAST WALL
5) CHECK ENTIRE HOUSE H2.5'S MISSING NAILS
6) COMPLY WITH DETAIL 7/DT1, 3/DT1
7) A03 TRUSS REQUIRES ENGINEER REPAIR
8) CHECK TRUSS BRACING
9) STOPPED INSPECTION