Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/03/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* WATER TEST THRU ROOF WASTE & VENT OK. 1) BAR SINK REQUIRES REVENT INTO AIR ADMITANCE VALVE VENT 2) PROVIDE PERMANENT CAP FOR DEMO DRAIN AT OLD KITCHEN SINK LOCATION. WITH VIEWING BY INSPECTOR PRIOR TO COVERING | |
| 01/31/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL PER YOU CITY APPROVED PLAN. 2) LONG RADIUS FITTING ARE REQUIRED ON ALL DRAINAGE. 3) LAV'S REQUIRE 1 1/2 DRAINAGE, 2" P-TRAP IS NOT ACCEPTABLE ON 1 1/4" TAIL PIECE DEVICES. 4) STOOL'S REQUIRE 4" DRAINAGE PER YOUR APPROVED PLAN |