Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04CM04663

Parcel: 12810082B


Addresses:

5340 E BROADWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T04CM04663

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
02/03/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :* WATER TEST THRU ROOF WASTE & VENT OK. 1) BAR SINK REQUIRES REVENT INTO AIR ADMITANCE VALVE VENT 2) PROVIDE PERMANENT CAP FOR DEMO DRAIN AT OLD KITCHEN SINK LOCATION. WITH VIEWING BY INSPECTOR PRIOR TO COVERING
01/31/2005 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) INSTALL PER YOU CITY APPROVED PLAN. 2) LONG RADIUS FITTING ARE REQUIRED ON ALL DRAINAGE. 3) LAV'S REQUIRE 1 1/2 DRAINAGE, 2" P-TRAP IS NOT ACCEPTABLE ON 1 1/4" TAIL PIECE DEVICES. 4) STOOL'S REQUIRE 4" DRAINAGE PER YOUR APPROVED PLAN