Permit: T04CM04662

Parcel: 115181240


Addresses:

535 W HELEN ST #01

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
12/29/2004 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*/1)ABS DWV BELOW GRADE OK. WATER TEST ONE RISER TO TEN FEET 2)OK TO COVER
12/28/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*/1)REQUIRE 2X PIPE DIAMETER BETWEEN W??? AT TRAP AND POINT OF VENT 2)A DBL SANTEE MAY BE USED WHEN BARREL IS TWO PIPE SIZES LARGER THAN THE LARGEST INLET. 3)BACK PITCHED SECTIONS NOT PERMITTED. 4)WATER TEST DOWN.