Permit: T04CM04660

Parcel: 137054840


Addresses:

5180 S 17TH AV #01


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T04CM04660

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
07/18/2005 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
1) DWV WATER TEST IS OK
2) OVERHEAD WATER DISTRIBUTION IS OK
3) GAS PRESSURE TEST IS OK
4) ALL CORRECTIONS HAVE BEEN MADE
07/15/2005 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
07/12/2005 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) SHALL PROVIDE WATER TEST ON DWV SYSTEM ALLTHE WAY TO TOP OF VENTS. 2) SHALL LOCATE HORIZONTAL VENT FOR KITCHEN SINKS 6" ABOVE FLOOD RIM LEVEL. 3) SHALL PROVIDE APPROVED STRAPING ON GAS LINE P-TRAP IS NOT APPROVED MATERIAL. 4) SHALL SECURE BETTER TUB VALVE @ WEST UNIT. 5) SHALL SHADE ENTIRE TRENCH FOR BLDG. SEWER AND PIPE SHALL BE LAID ON A FIRM BED. 6) SHALL PROVIDE A SWING JOINT ON PVC NO STRESS ON PIPE.