Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 04/07/2005 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :* CORRECTION MADE. (3) BACKFLOW CERTIFICATIONS TURNED IN. |
| 04/06/2005 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* 1) PROVIDE CLAMPS ON BOTH ENDS OF CONDENSATE DRAN TUBING CONNECTION AT LAV. 2) WATER HEATER T & P TO BE RIDGID FULL SIZE PIPING AND GRAVITY DRAIN TO RECEPTOR. 3) SECURE & SUPPORT WATER HEATER EXPANSION TANK. 4) ALL INDERECT DRAINS TO HAVE 1" AIR GAP. 5) SUPPORT DRAIN PIPIING FROM DIP WELLS. 6) MAKE WATER TIGHT ALL FIXTURES. |