Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T04CM04631
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/07/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* CORRECTION MADE. (3) BACKFLOW CERTIFICATIONS TURNED IN. | |
04/06/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE CLAMPS ON BOTH ENDS OF CONDENSATE DRAN TUBING CONNECTION AT LAV. 2) WATER HEATER T & P TO BE RIDGID FULL SIZE PIPING AND GRAVITY DRAIN TO RECEPTOR. 3) SECURE & SUPPORT WATER HEATER EXPANSION TANK. 4) ALL INDERECT DRAINS TO HAVE 1" AIR GAP. 5) SUPPORT DRAIN PIPIING FROM DIP WELLS. 6) MAKE WATER TIGHT ALL FIXTURES. |