Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/07/2007 | FRAMING | Approved | ||
| 05/02/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) EXCEPT GARAGE |
|
| 04/30/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HOW IS R-30 INSULATION INSTALLED IN 2 X 6 RAFTER ?? 2) PROVIDE GFI OUTLET FOR TEMP SERVICE 3) DUCT NOT PER PLAN 5) REVISE PLAN TO REFLECT AS BUILT |
|
| 04/25/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PENDING OTHER TRADES KITCHEN-EXCEPT GARAGE 2) PROVIDE WATER TEST TO ROOF TOP DWV SYSTEM 3) NAIL PROTECT KITCHEN ONLY 4) PROVIDE 12" CLEARANCE PEX FROM CANS 5) SECURE 4 GANG SWITCH BOX BOTH SIDES 6) MISSING CEILING FAN 7) PROVIDE GAS BOND 8) COMPLETE KITCHEN EXHAUST FAN |