Permit: T04CM04606

Parcel: 110034980

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM04606

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/08/2005 FRAMING Approved IVRS - Inspection :*
02/07/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LOOSE RED HEADS THROUGHOUT
2) COMPLY WITH DETAIL SHEARWALL MUST CONTINUE ABOVE DOOR AND REACH TOP PLATE
3) FIRESTOP TUB SHOES
4) RELOCATE CHASE FLEX DUCT UPSTAIRS
5) SEAL A/C LINE
6) SEAL REAR HOSE BIBS
7) NAIL PROTECT THROUGHOUT
8) NAIL PROTECT KITCHEN PLUMBING AT SOLE PLATE
9) DWV SYSTEM MUST BE FILLED TO ROOF TOPS
10) NAIL PROTECT PLUMBING SOLE PLATE STAIRWELL CLOSET
11) NO PRESSURE
12) FLEX DUCT IN CHASE UPSTAIRS RESTRICTED
13) RELOCATE MECHANICAL FLEX DUCT IN CHASE BY STAIRWELL
14) PROPERLY SECURE ALL 90'S TO ROOF