Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM04606
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/08/2005 | FRAMING | Approved | IVRS - Inspection :* | |
02/07/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LOOSE RED HEADS THROUGHOUT 2) COMPLY WITH DETAIL SHEARWALL MUST CONTINUE ABOVE DOOR AND REACH TOP PLATE 3) FIRESTOP TUB SHOES 4) RELOCATE CHASE FLEX DUCT UPSTAIRS 5) SEAL A/C LINE 6) SEAL REAR HOSE BIBS 7) NAIL PROTECT THROUGHOUT 8) NAIL PROTECT KITCHEN PLUMBING AT SOLE PLATE 9) DWV SYSTEM MUST BE FILLED TO ROOF TOPS 10) NAIL PROTECT PLUMBING SOLE PLATE STAIRWELL CLOSET 11) NO PRESSURE 12) FLEX DUCT IN CHASE UPSTAIRS RESTRICTED 13) RELOCATE MECHANICAL FLEX DUCT IN CHASE BY STAIRWELL 14) PROPERLY SECURE ALL 90'S TO ROOF |