Permit: T04CM04592

Parcel: 113061660


Addresses:

3200 N OLSEN AV

Inspection Status: Approved

Inspection History: STUCCO MESH

Date Description Inspector Results Comments
03/11/2006 STUCCO MESH Approved IVRS - Inspection :*
02/22/2006 STUCCO MESH Partial Approval IVRS - Inspection :*
1) PARTIAL APPROVAL EXCEPT MAIN SERVICE WALL
2) RELOCATE SMOKE DETECTOR HALLWAY 36" CLEARANCE FROM SUPPLY REGISTER
3) GROUND METAL CEILING BOX BEDROOM 2 AND CLOSET
4) NO WATER TEST DWV SYSTEM-PEX OK
5) NAIL PROTECT KITCHEN VTR TOP PLATES AND LANDING 1 1/2" VTR
6) NUTS MISSING BASE PLATES THROUGHOUT
7) GROUND ALL METAL BOXES
8) ALL CEILING FAN BOXES MUST BE RATED
9) FIRE STOP UPSTAIRS TUB SHOE
10) PIG TAIL MASTER WATER CLOSET SWITCH
11) FIRE BLOCK MASTER SOFFIT
12) EXPOSED WATER HEATER FLUE MASTER BEDROOM