Inspection History Details
Inspection Status: Approved
Inspection History: STUCCO MESH
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/11/2006 | STUCCO MESH | Approved | IVRS - Inspection :* | |
| 02/22/2006 | STUCCO MESH | Partial Approval | IVRS - Inspection :* 1) PARTIAL APPROVAL EXCEPT MAIN SERVICE WALL 2) RELOCATE SMOKE DETECTOR HALLWAY 36" CLEARANCE FROM SUPPLY REGISTER 3) GROUND METAL CEILING BOX BEDROOM 2 AND CLOSET 4) NO WATER TEST DWV SYSTEM-PEX OK 5) NAIL PROTECT KITCHEN VTR TOP PLATES AND LANDING 1 1/2" VTR 6) NUTS MISSING BASE PLATES THROUGHOUT 7) GROUND ALL METAL BOXES 8) ALL CEILING FAN BOXES MUST BE RATED 9) FIRE STOP UPSTAIRS TUB SHOE 10) PIG TAIL MASTER WATER CLOSET SWITCH 11) FIRE BLOCK MASTER SOFFIT 12) EXPOSED WATER HEATER FLUE MASTER BEDROOM |