Permit: T04CM04570

Parcel: 117110170

Inspection Status: Approved

Inspection History: PLUMBING - ABOVE CEILING

Permit Number - T04CM04570

Inspection Description - PLUMBING - ABOVE CEILING

Inspection Status - Approved

Date Description Inspector Results Comments
01/12/2005 PLUMBING - ABOVE CEILING Approved IVRS - Inspection :*
1) PLUMBING ABOVE 4TH FLOOR OK
2) OK TO COVER
11/23/2004 PLUMBING - ABOVE CEILING Not ready for Inspection IVRS - Inspection :*/1)THERE ARE TWO 6" CI STACKS IN CHASE. INSPECTOR NEEDS VERIFICATION THAT 2" IS CONNECTED TO WASTE STACK AND NOT VENT STACK 2)ALL HOT WATER TO BE INSULATED 3)HANGERS REQ'D AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES
10/25/2004 PLUMBING - ABOVE CEILING Not ready for Inspection IVRS - Inspection :*