Permit: T04CM04563

Parcel: 122160620


Addresses:

2209 N DODGE BL

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
05/10/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
01/31/2005 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1 SANITARY T FITTING CANNOT BE USED IN HORIZ DRAIN POSITION MUST USE A DIRECTIONAL FITTING APPRVD FOR DRAIN
2 RUBBER COUPLINGS ARE NOT ALLOWED FOR USE UNDER A SLAB
3 TOILET IN S.W. CORNER IS NOT PROPERLY VENTED. VENT MUST CONNECT DOWNSTREAM FROM THE TRAP AND CONNECT ABOVE THE CENTERLINE OF THE SEWER
01/19/2005 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :* NOT READY