Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T04CM04561
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/22/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
08/18/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 03040 -- EXPOSE TRACER WIRE AT WATER SERVICE 03035 -- CLOSET FLANGE INSPECTED IN RM 106 ALL CLOSET RINGS SHALL BE SECURELY FASTENED TO THE FLOOR W/CORROSION RESISTANT FASTENERS. UPC INSTALLATION STANDARDS 155 SEC 314.2 |
|
08/16/2006 | PLUMBING - INTERMEDIATE | Cancelled | ||
08/15/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* YOU HAVE INSPECTIONS THAT HAVE BEEN PARTIALLY APPROVED ONLY. THESE WILL NEED TO BE CALLED FOR AND APPROVED BEFORE FINAL INSPECTION. |
|
05/30/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* NEED TO VIEW ALL CLOSET FLANGES CORRECTLY INSTALLED. |
|
05/26/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* COMMUNITY BUILDING INSPECTION, YARD WATER CONNECTION TO SERVICE OK. ROOF DRAINS - OK TEST ON DWV - OK INSTALL HAMMER ARRESTOR AT URINALS INSTALL T&P AT MANAGERS WH CLOSET FLANGES, FLOOR DRAINS, MOP SINK & TUB NOT SET. GAS TEST ON 60 PSI GAUGE HOLDING 16 PSI. RETEST AFTER COVERING. |
|
04/26/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER PIPING 2 1/2" OVERHEAD SOUTH OK & TIE IN UNDERGROUND OK SOUTH, EAST, NORTH BUILDING OK EXCEPT LAUNDRY 1. NEED TO SEE SHOWER PAN TEST PRIOR TO TILE. |
|
04/21/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER TEST WASTE & VENT THRU ROOF FROM LAUNDRY ROOM NORTH THEN WEST ROOMS #121 - 140 INCLUDING 2ND LEVEL. WATER PIPING THIS AREA IN WALL & OVERHEAD OK PENDING CONNECTION TO AREA AT ENTRY FROM MAIN FOR UNDUE STRAIN ON CPVC AT UNIT VALVE LOCATIONS. RAIN DRAIN & OVERFLOW RAIN DRAIN WATER TEST THIS AREA OK SUPPORT AT 4' INTERVALS ON HORIZONTAL. |
|
04/12/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* INSTALL WATER PIPING MAINS PER PLAN OR PROVIDE REVISED APPROVED PLAN OF INSTALLATION. |
|
04/06/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WASTE & VENT WATER TEST THRU ROOF UNITS 115 THRU 126 AND ABOVE WATER TEST IN UNITS 115 THRU 126 AND ABOVE OK |
|
04/05/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE CLEANOUT AT 1ST FLOOR KITCHEN SINK. 2. PROVIDE FALL ON STOOL DRAIN ARM. 3. PROVIDE CORRECT SUPPORT ON ALL PIPING. 4. HAVE ALL PIPING UNDER TEST AT TIME OF INSPECTION. |
|
04/03/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELLED BY PHONE. |
|
03/30/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
03/29/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
03/27/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* UNITS 101, 102, 103, 104 AND ABOVE ON 2ND FLOOR WASTE & VENT THRU ROOF OK 60 PSI TEST WATER PIPING IN UNITS OK 1. NEED TO SEE WATER MAINS WITH TEST TIED IN AT LATER DATE |
|
03/22/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER TEST WASTE & VENT ONLY THRU ROOF NORTH BUILDING INCLUDING NORTHEAST (4) UNITS OR FOR TUB ENCLOSURE SHEETROCK PER PLUMBING. 1. NEED ADDITION OF CLEANOUTS PER PLAN NORTHEAST DOWNSTAIRS 3" STOOL AREA. 2. RETEST SOUTH NORTHEAST UNIT LEAK ON STOOL BUSHING DOWNSTAIRS & REVERT SAME AREA UPSTAIRS. |
|
03/13/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER TEST IS OK FOR TUB AREA ROCK ONLY 1ST & 2ND FLOOR EAST BUILDING SHALL RETEST WASTE & VENT IN ENTIRETY WHEN CORRECT SUPPORTS IN PLACE THIS AREA. TUB AREA 1ST & 2ND FLOOR SOUTH BLD. OK FOR ROCK ONLY SHALL RETEST THRU ROOF ALL PIPING THIS AREA ALSO. |
|
03/09/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) WATER TEST WASTE AND VENT 1ST FLOOR ONLY EAST BLDG OK FOR TUB ROCK 2) NEED REPAIR ON LEAK AT 3" RISER JANITOR SINK AT LAUNDRY AREA 3) NEED TEST THRU ROOF AT LATER DATE WITH ALL CORRECTIONS PER DISCUSSION WITH DENNIS (PLUMBER) |
|
02/24/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. REPAIR LEAK AT KITCHEN SINK 2. PROVIDE CLEANOUTS PER PLAN 3. SUPPORT PIPING AT CORRECT INTERVALS WITH APPROVED METHODS. 4. VENT PIPING & REVERT PIPING TO RISE TO TERMINATION. |
|
02/22/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
02/06/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
10/15/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :HAD A MEETING WITH THE G.C ON FIRE MAIN |