Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04CM04561


Addresses:

370 N PANTANO RD


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T04CM04561

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
08/22/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
08/18/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
03040 -- EXPOSE TRACER WIRE AT WATER SERVICE
03035 -- CLOSET FLANGE INSPECTED IN RM 106
ALL CLOSET RINGS SHALL BE SECURELY FASTENED TO THE FLOOR W/CORROSION RESISTANT FASTENERS.
UPC INSTALLATION STANDARDS 155 SEC 314.2
08/16/2006 PLUMBING - INTERMEDIATE Cancelled
08/15/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
YOU HAVE INSPECTIONS THAT HAVE BEEN PARTIALLY APPROVED ONLY. THESE WILL NEED TO BE CALLED FOR AND APPROVED BEFORE FINAL INSPECTION.
05/30/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
NEED TO VIEW ALL CLOSET FLANGES CORRECTLY INSTALLED.
05/26/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
COMMUNITY BUILDING INSPECTION, YARD WATER CONNECTION TO SERVICE OK.
ROOF DRAINS - OK TEST ON DWV - OK
INSTALL HAMMER ARRESTOR AT URINALS
INSTALL T&P AT MANAGERS WH
CLOSET FLANGES, FLOOR DRAINS, MOP SINK & TUB NOT SET.
GAS TEST ON 60 PSI GAUGE HOLDING 16 PSI.
RETEST AFTER COVERING.
04/26/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER PIPING 2 1/2" OVERHEAD SOUTH OK & TIE IN UNDERGROUND OK
SOUTH, EAST, NORTH BUILDING OK EXCEPT LAUNDRY
1. NEED TO SEE SHOWER PAN TEST PRIOR TO TILE.
04/21/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER TEST WASTE & VENT THRU ROOF FROM LAUNDRY ROOM NORTH THEN WEST ROOMS #121 - 140 INCLUDING 2ND LEVEL. WATER PIPING THIS AREA IN WALL & OVERHEAD OK
PENDING CONNECTION TO AREA AT ENTRY FROM MAIN FOR UNDUE STRAIN ON CPVC AT UNIT VALVE LOCATIONS.
RAIN DRAIN & OVERFLOW RAIN DRAIN WATER TEST THIS AREA OK
SUPPORT AT 4' INTERVALS ON HORIZONTAL.
04/12/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
INSTALL WATER PIPING MAINS PER PLAN OR PROVIDE REVISED APPROVED PLAN OF INSTALLATION.
04/06/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WASTE & VENT WATER TEST THRU ROOF UNITS 115 THRU 126 AND ABOVE WATER TEST IN UNITS 115 THRU 126 AND ABOVE OK
04/05/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. PROVIDE CLEANOUT AT 1ST FLOOR KITCHEN SINK.
2. PROVIDE FALL ON STOOL DRAIN ARM.
3. PROVIDE CORRECT SUPPORT ON ALL PIPING.
4. HAVE ALL PIPING UNDER TEST AT TIME OF INSPECTION.
04/03/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED BY PHONE.
03/30/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
03/29/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
03/27/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNITS 101, 102, 103, 104 AND ABOVE ON 2ND FLOOR WASTE & VENT THRU ROOF OK
60 PSI TEST WATER PIPING IN UNITS OK
1. NEED TO SEE WATER MAINS WITH TEST TIED IN AT LATER DATE
03/22/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER TEST WASTE & VENT ONLY THRU ROOF NORTH BUILDING INCLUDING NORTHEAST (4) UNITS OR FOR TUB ENCLOSURE SHEETROCK PER PLUMBING.
1. NEED ADDITION OF CLEANOUTS PER PLAN NORTHEAST DOWNSTAIRS 3" STOOL AREA.
2. RETEST SOUTH NORTHEAST UNIT LEAK ON STOOL BUSHING DOWNSTAIRS & REVERT SAME AREA UPSTAIRS.
03/13/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER TEST IS OK FOR TUB AREA ROCK ONLY 1ST & 2ND FLOOR EAST BUILDING SHALL RETEST WASTE & VENT IN ENTIRETY WHEN CORRECT SUPPORTS IN PLACE THIS AREA.
TUB AREA 1ST & 2ND FLOOR SOUTH BLD. OK FOR ROCK ONLY SHALL RETEST THRU ROOF ALL PIPING THIS AREA ALSO.
03/09/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) WATER TEST WASTE AND VENT 1ST FLOOR ONLY EAST BLDG OK FOR TUB ROCK
2) NEED REPAIR ON LEAK AT 3" RISER JANITOR SINK AT LAUNDRY AREA
3) NEED TEST THRU ROOF AT LATER DATE WITH ALL CORRECTIONS PER DISCUSSION WITH DENNIS (PLUMBER)
02/24/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. REPAIR LEAK AT KITCHEN SINK
2. PROVIDE CLEANOUTS PER PLAN
3. SUPPORT PIPING AT CORRECT INTERVALS WITH APPROVED METHODS.
4. VENT PIPING & REVERT PIPING TO RISE TO TERMINATION.
02/22/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
02/06/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
10/15/2005 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :HAD A MEETING WITH THE G.C ON FIRE MAIN