Permit: T04CM04561


Addresses:

370 N PANTANO RD


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T04CM04561

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/18/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
09/15/2006 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1. CONDUCTOR TO BE IDENTIFIED FOR UNGROUNDED CONDUCTORS.
2. PLEASE PROVIDE ACCESS FOR EAST ROOF
3. INSTALL ALL LIGHT FIXTURES AS PER PLANS
4. FINISH CHIMES
5. SUPPORT VDV CABELING (NEW) IN COMMUNITY CENTER
09/14/2006 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
THERE IS NO ROOF ACCESS TO EAST BUILDING FOR INSPECTION.

OK SOUTH BUILDING
OK EAST BUILDING EXCEPT ROOF
09/13/2006 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
OK LOUNGE
OK ELEVATOR SOUTH
OK LAUNDRY

1. LABEL PANELS
2. DISCONNECTING MEANS FOR WATER HEATER & FAN COILS
3. FILL UNUSED OPENING IN LIGHT BARS
4. FINISH EM LIGHTING MIDDLE STAIRWELL OUTSIDE.

*RECEIVED CHECK #24838 FOR $108.00
09/12/2006 ELECTRIC - FINAL Partial Approval ROOF
1. TIGHTEN LOOSE FITTINGS
2. LABEL DISCONNECTS
3. PLEASE VERIFY LISTING FOR FITTINGS

BLDG
1. EM LIGHTING NOT WORKING
2. BOXES MORE THAN 1/4" FROM BOX TO SURFACE NEED APPROVED EXTENDER RING 314.20
3. NEED DISCONNECTING MEANS FOR FAN COIL.

OK BOTTOM FLOOR EXCEPT AS NOTED
SOUTH

RECEIVED CHECK #24835 FOR $108.00
09/11/2006 ELECTRIC - FINAL Partial Approval 1. LOCKOUT FOR FAN COIL.
OK COMMUNITY CENTER & MANAGER UNIT
OK 2ND FLOOR SOUTH

RECEIVED CHECK #24852 FOR $108.00
09/08/2006 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1. NEED PANEL DIRECTORY'S 408.4
2. USE ADEQUATE SUPPORTS ABOVE PANEL
3. MAKE UP FIRE PLACE
4. DISCONNECTING MEANS FOR WATER HEATER
5. FINISH ROOF

*CHANDELIERS ON BACK ORDER
09/06/2006 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*