Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/10/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 01/24/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ROOF NAILING INTO BLOCKING AT BEARING INCOMPLETE 2) ROOF NAILING INCOMPLETE GARAGE S.W. TRANSFER 3) NEED ENGINEER APPROVAL ON ALTERNATE SHEAR TRANSFER 4) AT GARAGE TO BOTTOM CHORD TRUSS 5) ? HANGERS BEAM TO POSTS 6) PLAN CALLS FOR 4 X 10 BEAM PORCH 7) STOPPED INSPECTION |
|
| 01/18/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL PROTECT ELECTRIC FROM OUTSIDE AND PLUMBING 2) REPAIR SHEAR AT BACK PATIO 3) ADD STUD AT FRONT COLUMN F/HOLDOWN 4) NO TRUSS CALC'S 5) NO ACCESS TO ROOF |
|
| 01/13/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) D01P TRUSS REPAIR NOT DONE PER APPROVED DETAIL, D01P, TRUSS NOT ON CALC'S 2) CHECK ROOF FOR NAILING AND EXPOSED NAILS AND STAPLES 3) SEE AL PREVIOUS INSPECTIONS |
|
| 01/03/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :*/1)CANCELLED ON SITE BY STEVE | |
| 12/30/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 12/29/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED BY TERRY (R.A.) |
|
| 12/27/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* |
|
| 12/23/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) LABEL PERMIT CARD WITH OPTIONS, IF NONE WRITE NONE. NO OPTIONS 2) D01P TRUSSES 4 TOTAL AT REAR OF HOUSE, REQUIRE A RAT RUN, SEE DRAWINGS, ALSO ONE TRUSS IS INSTALLED REVERSED 3) #7 SHEAR WALL AT REAR, GETS 5/8 DIAMETER BOLTS 24" ON CENTER NOT EXPANSIVE TYPE, ASK ENGINEER FOR ALTERNATE RED LINE PLANS FOR CONCRETE CONTRACTOR 4) MISSED NAILING ON ROOF MARKED IN BLACK 5) SHEAR PANELS BETWEEN TRUSSES, PLAN CALLS FOR A PANEL AT 24" ON CENTER, SAME AS A WALL, IF YOU BUILD A 4' LONG WALL, STUDS AT 24" ON CENTER YOU WOULDN'T PUT ONE STUD AT 24" AND LEAVE THE OTHER STUDS OUT ? |