Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/21/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/02/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) MAIN HOUSE OK 2) PORCHES INCOMPLETE |
|
| 03/07/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ROMEX HANGING LOOSE S.W. BEDROOM 2) FLEX DUCT EXCESSIVELY COMPRESSED 3) WALL TIES MISSING MASONRY ROCK SHEAR WALL 4) NEED ADDITIONAL DETAIL ON FIRE PLACE HEARTH EXTENSION 2 EACH SIDE OF FIRE PLACE 5) MOVE ELECTRIC OUTLET RIGHT SIDE OF FIRE PLACE 6) FIRE PLACE MISSING HEADER PER PLAN 7) WINDOW OMITTED EAST WALL 8) SUPPORT DIRTY ARM BATH AT TERMINATION STUB OUT OF WALL 9) SECURE LOOSE STUD WALLS AT CLOSET DOORS 10) FIREBLOCK ALL FURRED DOWN AREAS 11) INSTALL NAILS CAN LIGHT HANGERS 12) ELECTRIC ROMEX STRETCHED TO TIGHT DROPPED CEILING NORTH OF WASHER AREA 13) REPAIR-REPLACE DAMAGED BLOCKING GARAGE S.W. CORNER 14) ATTACH ROMEX TO STUDS THROUGHOUT 15) ALL ELECTRIC WIRES TO TERMINATE IN BOXES 16) INSTALL BANG PLATE DRYER VENT-HOLE IN BLOCKING 17) INSTALL BANG PLATEWATER LINE SOUTH WALL DRYER AREA 18) STOPPED INSPECTION-TOO MANY ITEMS INCOMPLETE |
|
| 02/21/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |