Permit: T04CM04545

Parcel: 136287840


Addresses:

7452 E POINCIANA PL


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T04CM04545

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
03/28/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/09/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
02/24/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :* 1) PLAN CALLS FOR H-3 HEADERS 3-2X8 AS SHOWN. 2) GIRDER TRUSS AT EAST BEDROOM APPEARS TO BE WRONG TYPE, NEED TRUSS SHOP DRAWINGS. 3) TRUSS TO GIRDER HANGERS USE 16 D COMMON NAILS PER HANGER CAT.4) NAIL ALL SHEAR PANELS WITH 8D SPOT NAILS, HORIZ JOINS. 5) DON'T LOAD ROOF. 6) FIND DETAIL FOR ATTACHING SHEAR WALL TO ROOF STRUCTURE ( TRANSFER)