Permit: T04CM04531

Parcel: 122080840


Addresses:

2133 N WALNUT AV

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
12/27/2004 ROOF NAILING Approved IVRS - Inspection :*
12/23/2004 ROOF NAILING Not ready for Inspection IVRS - Inspection :*
12/21/2004 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OSB SHEATHING CANNOT BE INSTALLED WITH GRAIN PARALLEL TO TRUSSES. YOU MAY INSTALL SUPPORT BLOCKS BETWEEN TRUSSES AT 24" ON CENTER
2) MAKE UP ALL GROUNDS (CONNECT AND SECURE WITH MECHANICAL FASTENERS)
3) OVER FRAMED AREA OF ROOF MUST HAVE HEEL OF BIRD MOUTH (BOTTOM) OF RAFTER BEARING ON 2 X 8 VALLEY BOARD
4) OVER FRAME MUST HAVE COLLAR TIES AT 4' ON CENTER