Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04CM04525

Parcel: 137050040

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
11/13/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
1. VENT PIPING ON ROOF WITH 10' OF AIR INTAKE GO 3' ABOVE AIR INTAKE.
2. PLUMBING GAS PRESSURE TEST 03050
11/07/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
11/02/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. PROVIDE CLEANOUT FOR MOP SINK.
2. PROVIDE TEST ALL ABS PIPING IN WALLS
3. REDLINE DRAWING FOR GAS PIPING
4. PROVIDE APPROVAL SUPPORT FOR GAS PIPING
(TWO HOLE CLAMPS).
5. WATER PIPING IN WALL TEST OK
10/02/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*