Permit: T04CM04525

Parcel: 137050040

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
06/21/2006 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
OK TO COVER
06/19/2006 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
NO TEST ON ABS ROUGH SOIL - 10' HEAD WATER TEST
05/09/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
ROUGH PLUMBING IN NEW ADDITION OK - FLOOR DRAIN AND FS NOT YET INSTALLED.
WILL NEED TO SEE FLOOR DRAIN AND PIPING INSIDE EXISTING BUILDING.
05/08/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
GREASE WASTE, RESTROOMS INSIDE BUILDING W/10' TEST OK
CORRECT VENT FOR FLOOR DRAIN - USE CORRECT DRAINAGE FITTING FOR HORIZONTAL VENT BELOW FLOOD RIM
PROVIDE 2% SLOPE ON HORIZONTAL VENT BELOW FLOOD RIM.