Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM04517
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/08/2005 | FRAMING | Approved | IVRS - Inspection :* | |
04/07/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
04/05/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL H2.5 AT ALTERATION STUDS PER PLAN AT ALL BEARING WALL STUDS TO PROVIDE CONTINUE TIE FROM FLOOR TO ROOF PAGE 4-B 2) NAIL PROTECT ROMEX UNDER 1 1/4" CLEARANCE MARKED AT LAUNDRY WALL 3) DO NOT INSULATE THESE AREAS |
|
04/01/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SILL PLATES MUST HAVE AT LEAST TWO ANCHOR BOLTS. BOLTS MUST BE WITHIN 12" OF ENDS AND SPLICES AND EVERY 6' THERE AFTER 2) PLAN CALLS FOR 2 EACH PAHD 42 HOLDOWNS ON S.W. CORNER, NOT INSTALLED PROVIDE RETRO FIT 3) SMOKE DETECTOR MUST BE 36" FROM AIR REGISTER 4) INTERIOR BEARING WALL BETWEEN CLOSET AND LAUNDRY MUST BE CLIPPED AND ANCHORED WITH H2.5 CLIPS AND ANCHOR BOLTS PER ITEM #1 ALSO BEARING FURR OUT WALL 5) LTT20 HOLDOWN |
|
03/28/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) GROUND ALL METAL ELECTRIC BOXES 2) GAS NOT COMPLETED TO GAS PACK ON ROOF 3) STUCCO J-METAL BOTTOM INCORRECTLY INSTALLED 4) NO TEST DWV 5) INSTALL BOTTOM PLATE CONNECTIONS TO CONCRETE 6) INSTALL H2.5'S BEARING WALLS RAFTER TO PLATE; PLATE TO STUD AND STUD TO BOTTOM PLATE 7) STOPPED INSPECTION |
|
03/23/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIREBLOCK MISSING AT SHOWER VENT 2) KING STUD OVER KNOTCHED KITCHEN SINK WINDOW 3) PROVIDE 16 GUAGE STRAPS WITH 8-EACH 16D COMMONS TO OVERNOTCH 4) GROUND EXTERIOR METAL BOX 5) FILL WASH VENTS 6) NO WATER DWV SYSTEM TO ROOF 7) SECURE ALL 90 VENTS THROUGH ROOF 8) NAIL PROTECT SHOWER 1 1/2" VENT 9) NAIL PROTECT BATH VANITY VENT AT TOP PLATE 10) BLOCK REGISTERS 3 SIDES 11) UNABLE TO LOCATE PLAN OR INSPECTION CARD 12) STOPPED INSPECTION |
|
01/31/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |