Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/23/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/21/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 4' SECTION FO GARAGE SHEARWALL WEST SIDE OF 3' MAN DOOR SHEAR TRANSFER BREAKS BETWEEN DLBE TOP PLATES (NON CONTINOUS). REPAIR AS YOU DID OVER OTHER OPENINGS |
|
| 12/17/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS NOT CORRECTED |
|
| 12/08/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SW3 REQUIRES ANCHOR BOLTS AT 32" CENTER MINIMUM 2) 2 BOLTS PER PIECE MINIMUM 8" FROM ENDS 3) HOLDOWNS NOT NAILED OFF 4) GARAGE SW3 REQUIRES CONTINOUS SHEAR BOTTOM PLATE TO TOP CHORD TRUSS (HORIZONTAL JOINT OCCURES AT BREAK BETWEEN DBL PLATES) |
|
| 12/07/2004 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | IVRS - Ri canceled |