Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/08/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 03/15/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) USE 16D'S AT PORCH HARDWARE 2) NEED DETAIL OF LEDGER ATTACHMENT, IS WALL SOLID MASONRY ? 3) OK TO INSULATE/DRYWALL |
|
| 02/24/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 02/23/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GLUE LAM BEAM POSTS NOT INSTALLED. 2) S.W PORCH LEDGER NUT BOLTED TO STRUCTURE. 3) PROVIDE CITY APPROVED DETAIL FOR LEDGER CONNECTIONS TO EXISITING HOUSE. 4) OUTER FRAME MISSING 2X4 LAE SEE 3/5. 5) HOLD DOWNS MUST BE CONNECTED TO FULL LENGTH DOUBLE STUBS ?? 6) NORTH WALL SHEATHING NOT NAILED TO ONE STUD. 7) DOULBE TRUSS REQUIRES DOUBLE HANGER. 8) PROVIDE TRIPPLE 2X POST UNDER TRIPPLE GIRDER TRUSS WEST END. 9) NO LADDER ACCESS TO ROOF |
|
| 02/19/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |