Permit: T04CM04500

Parcel: 112040400

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/08/2005 FRAMING Approved IVRS - Inspection :*
03/15/2005 FRAMING Partial Approval IVRS - Inspection :*
1) USE 16D'S AT PORCH HARDWARE
2) NEED DETAIL OF LEDGER ATTACHMENT, IS WALL SOLID MASONRY ?
3) OK TO INSULATE/DRYWALL
02/24/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
02/23/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) GLUE LAM BEAM POSTS NOT INSTALLED. 2) S.W PORCH LEDGER NUT BOLTED TO STRUCTURE. 3) PROVIDE CITY APPROVED DETAIL FOR LEDGER CONNECTIONS TO EXISITING HOUSE. 4) OUTER FRAME MISSING 2X4 LAE SEE 3/5. 5) HOLD DOWNS MUST BE CONNECTED TO FULL LENGTH DOUBLE STUBS ?? 6) NORTH WALL SHEATHING NOT NAILED TO ONE STUD. 7) DOULBE TRUSS REQUIRES DOUBLE HANGER. 8) PROVIDE TRIPPLE 2X POST UNDER TRIPPLE GIRDER TRUSS WEST END. 9) NO LADDER ACCESS TO ROOF
02/19/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*