Permit: T04CM04463

Parcel: 140295120

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM04463

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/15/2004 FRAMING Approved IVRS - Inspection :*
12/14/2004 FRAMING Denied 1) PROVIDE 1" CLEARANCE AT FLUE PIPE
2) SEAL PENETRATIONS AT TUBS
3) SECURE PLUMBING GOING TO 2ND FLOOR
4) STRAP SHEARWALL AT GARAGE
12/13/2004 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) PROVIDE PROOF OF SOUTH WEST HOLDOWN INSTALLED
2) SOUTH EAST HOLDOWN NOT NAILED
3) EXTERIOR CLIP NOT APPROVED-CALL IN
4) GARAGE LSL NOT NAILED
5) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE
6) NO DWV WATER TEST
7) STOPPED INSPECTION
8) HOUSE NOT COMPLETE ENOUGH TO INSPECT