Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM04463
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/15/2004 | FRAMING | Approved | IVRS - Inspection :* | |
12/14/2004 | FRAMING | Denied | 1) PROVIDE 1" CLEARANCE AT FLUE PIPE 2) SEAL PENETRATIONS AT TUBS 3) SECURE PLUMBING GOING TO 2ND FLOOR 4) STRAP SHEARWALL AT GARAGE |
|
12/13/2004 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) PROVIDE PROOF OF SOUTH WEST HOLDOWN INSTALLED 2) SOUTH EAST HOLDOWN NOT NAILED 3) EXTERIOR CLIP NOT APPROVED-CALL IN 4) GARAGE LSL NOT NAILED 5) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE 6) NO DWV WATER TEST 7) STOPPED INSPECTION 8) HOUSE NOT COMPLETE ENOUGH TO INSPECT |