Permit: T04CM04451

Parcel: 111032230


Addresses:

3412 N KLEINDALE PL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/04/2005 FRAMING Approved IVRS - Inspection :*
12/22/2004 FRAMING Not ready for Inspection IVRS - Inspection :*
1) COMPLETE LATH THEN RECALL
12/21/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIRE STOP PLUMBING WALL BY KITCHEN
2) FIRESTOP KITCHEN HOOD
12/20/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REPAIR OR REPLACE TOP DBL PLATE AT KITCHEN
2) FIRE STOP PLUMBING WALL IN LAUNDRY ROOM
3) FIRE STOP KITCHEN EXHAUST AND MASTER PLUMBING VENTS
4) STRAP MECHANICAL IN MASTER BEDROOM
5) STRAP MECHANICAL AWAY FROM CANS
6) OK TO INSULATE
12/17/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIRE STOP KITCHEN EXHAUST TO PLATES OVER KNOTCHED
2) TOP PLATE OVER KNOTCHED AT PLUMBING WALL 2 X 6 LAUDNRY ROOM FIRE STOP
3) ALL WINDOWS NOT INSTALLED
4) NAIL PROTECT 220 LINE EAST WALL
5) MAKE UP OUTLETS AT KITCHEN EXTERIOR WALL PER PLAN
6) PROVIDE PROPER 6" CLEARANCE TO ALL CANS IN KITCHEN
7) SUBMIT REVISION TO CHANGE IN MASTER BATHROOM TUB TO CITY OF TUCSON WITH STAMPED APPROVAL
8) TIGHTEN ALL RED HEADS
9) NAIL PROTECT ROMEX THROUGHOUT HOUSE
10) MECHANICAL REGISTERS BLOCK 3 SIDES
11) STOPPED INSPECTION IN BATHROOM
12) TO MANY ITEMS
11/30/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) MUST HAVE ALL INTERMEDIATES WITH LATH COMPLETED PRIOR TO THIS INSPECTION
2) HOLDOWNS NOT PER PLAN
3) NEED POSITIVE CONNECTION REAR PORCH CONCRETE
4) TO PLATE TO POST TO BEAM TO TRUSSES CONTINOUS
5) 2 BOLTS REQUIRED BOTTOM PLATES EACH 4' SECTIONS SHEARWALLS
6) NAILS SET TO DEEP ON EXTERIOR
7) STOPPED INSPECTION ON EXT. CLIP/EXT. SHEATHING