Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/13/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 04/12/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CONTRACTOR WILL RESCHEDULE FOR TOMORROW |
|
| 04/10/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) OK TO INSULATE 2) 1 HR RATING NOT MAINTAINED AT REAR PORCH 3) 5/8" ROCK TO RUN UP TO UNDERNEATH OF ROOF SHEATHING 4) NO DETAILS ON PLAN 5) NO RATED ROCK AT REAR PORCH 6) INSTALL 5/8" X AT GARAGE AND PORCH CALL FOR INSPECTION BEFORE CEILING BOARD IS INSTALLED, THAN INSTALL NAILER FOR CEILING |
|
| 04/07/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* |
|
| 04/06/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH PREVIOUS INSPECTION |
|
| 04/05/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRESTOP SLIDING GLASS DOOR AT PATIO 2) LOOSE PLATE KITCHEN REFRIDGERATOR WING WALL 3) OVER KNOTCH DRYER VENT OVER SPAN 4) FIRESTOP HALLWAY DROPPED CEILING 5) NAIL PROTECT THROUGHOUT 6) ANCHOR BOLTS MISSING THROUGHOUT 7) SHEAR BLOCKING N.E. CORNER MISSING 8) SECURE BEDROOM WALL TOP PLATE BEDROOM 3 9) NAILER MISSING BEDROOM 2 NORTH TOP PLATE 10) FIRESTOP MASTER SHOWER 11) LADDER BACK ENTRY WALL |