Permit: T04CM04445

Parcel: 111032180


Addresses:

3411 N KLEINDALE PL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/11/2005 FRAMING Approved IVRS - Inspection :*
01/10/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REPAIR OVER KNOTCHED STUD AND TOP PLATE IN LAUNDRY ROOM
2) REPAIR OVER KNOTCHED DBL TOP PLATES ABOVE STOVE EXHAUST. EXHAUST OUTSIDE WALL 2 X 4 1 ? OPENING
3) BLOCK ALL REGISTERS 3 SIDES
4) SECURE 4 WAY BOX AT ENTRY
5) NAIL PROTECT PEX TO WATER HEATER AT TOP PLATE IN GARAGE
6) NO WATER IN SYSTEMS
7) GROUT TUB SHOE
8) SHIM NEEDED HEADERS
9) FIRESTOP MASTER SHOWER CHASE
10) FIRESTOP MASTER WATER CLOSET ROOM AT 3" VENT TOP PLATE
12/28/2004 FRAMING Not ready for Inspection IVRS - Inspection :*
1) INSTALL STUCCO MESH
2) PLEASE INSTALL STUCCO MESH BEFORE ALL INTERMEDIATE INSPECTIONS