Permit: T04CM04443

Parcel: 125071810

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T04CM04443

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/26/2005 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
04/21/2005 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) NO APPROVED PLAN ON SITE. NO RED LINES SHOWING ANY CHANGES-YET CONTRACTOR WISHES TO PRESS ON
2) WET VENTING LIMITED TO VERTICAL DRAINAGE PIPING RECEIVING DISCHARGE FROM TRAP ARMS
3) CLOSET FLANGES TO BE SECURED WITH ? OR BRASS SCREWS
4) ALL OVERHEAD PIPING TO BE SECURED TO TABLE 3-1 AND IS-5 94 UPC
5) NO PROVISION MADE FOR INSULATING HOT WATER PIPING