Inspection History Details
Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
Permit Number - T04CM04427
Inspection Description - SHEET ROCK NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/26/2004 | SHEET ROCK NAILING | Approved | IVRS - Inspection :* | |
10/25/2004 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :*/ 1) NORTH STOREROOM WALL-FITTING ROOM | |
10/22/2004 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* | |
10/18/2004 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :FIRE RATED WALLS ARE REQUIRED TO BE CONSTRUCTED WITH TIGHT JOINTS USG REQUIRES 1/8" MAX BETWEEN SHEETROCK ICBO REQUIRES 1/16" MAX FOR A TIGHT JOINT YOUR WEST WALL IS NOT PROPERLY CONSTRUCTED |
|
10/15/2004 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :NOTE: EAST DEMISING WALL IS NOTED AS EXISTING PLEASE HAVE PARK MALL MGMT PROVIDE PERMIT THAT ALLOWED THEM TO BUILD THAT WALL ALSO - MAINTAIN 1 HOUR SEPERATION AS REQUIRED BY IBC, BOTH SIDES OF WALL MUST BE SHEETROCKED |