Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/31/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :*AP | |
| 01/28/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* COMPLY W/ REQ'D SHEAR WALL LENGTH + TRANSFER SHEAR AT ROOF |
|
| 01/26/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL 2-16D COMMONS AT ALL WIND BRACE TOP AND BOTTOM PLATES 2) MISSING CLIP WEST WALL BOTTOM PLATE 3) EXPOSE PORCH COLUMN BASE 4) LOOSE SHEETS 5) DIAPHRAM NAILING 6) COMPLY WITH SHEARWALL SCHEDULE 4 AND 3. SHEARPANEL MUST REACH DBL TOP PLATE |