Permit: T04CM04375

Parcel: 140383630


Addresses:

5870 E CHAUCERS DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/01/2005 FRAMING Approved IVRS - Inspection :*
01/31/2005 FRAMING Partial Approval IVRS - Inspection :*
SHIM ALL HEADERS BLOWN FIRE BLOCKS, CHECK ALL AREAS PAINTED ORANGE BY SUPER
OK TO INSULATE
01/28/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
REFEE DUE ON 1035
REPAIR HOLES IN GARAGE SHEAR WALL
DWV HOLDING WATER THROUGH ROOF-OK
INSTALL BANG PLATES PLB AND ELECTRIC TTHROUGHOUT
SECURE PEX PIPE AWAY FROM THE LATH AT WATER SERVICE ENTRANCE
REBUILD GARAGE SHEAR WALL PER DETAIL
REPLACE DAMAGED TOP PLATES HALLWAY
01/26/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NOT READY, CANCEL PER CONTRACTOR
01/24/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER CONTRACTOR
01/20/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NOT READY, CANCELLED PER CONTRACTOR
01/19/2005 FRAMING Denied 1) GAS LINE NOT RUN
2) H20 SERVICE PUSHING ON LATH EAST SIDE BANG PLATE ALL PIPES
3) NEED VERT, BACKING REAR SHOWER
4) SHEAR WALL #1 GARAGE H2.5 EACH STUD, A35 F EACH CORNER OF PANEL TO TOP PLATE, TOE NAIL 16" ON CENTER 16D, TOP OF PANEL IS SUPPOSED TO BE NAILED TO ROOF DECK 10/DT1
5) BROKEN TOP PLATE HALL WAY
6) FINISH LATH
7) H20 TEST AIR 50 POUNDS OK
8) NEED H20 TEST REAR SHOWER PAN