Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/01/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/31/2005 | FRAMING | Partial Approval | IVRS - Inspection :* SHIM ALL HEADERS BLOWN FIRE BLOCKS, CHECK ALL AREAS PAINTED ORANGE BY SUPER OK TO INSULATE |
|
| 01/28/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* REFEE DUE ON 1035 REPAIR HOLES IN GARAGE SHEAR WALL DWV HOLDING WATER THROUGH ROOF-OK INSTALL BANG PLATES PLB AND ELECTRIC TTHROUGHOUT SECURE PEX PIPE AWAY FROM THE LATH AT WATER SERVICE ENTRANCE REBUILD GARAGE SHEAR WALL PER DETAIL REPLACE DAMAGED TOP PLATES HALLWAY |
|
| 01/26/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY, CANCEL PER CONTRACTOR |
|
| 01/24/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER CONTRACTOR |
|
| 01/20/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY, CANCELLED PER CONTRACTOR |
|
| 01/19/2005 | FRAMING | Denied | 1) GAS LINE NOT RUN 2) H20 SERVICE PUSHING ON LATH EAST SIDE BANG PLATE ALL PIPES 3) NEED VERT, BACKING REAR SHOWER 4) SHEAR WALL #1 GARAGE H2.5 EACH STUD, A35 F EACH CORNER OF PANEL TO TOP PLATE, TOE NAIL 16" ON CENTER 16D, TOP OF PANEL IS SUPPOSED TO BE NAILED TO ROOF DECK 10/DT1 5) BROKEN TOP PLATE HALL WAY 6) FINISH LATH 7) H20 TEST AIR 50 POUNDS OK 8) NEED H20 TEST REAR SHOWER PAN |