Permit: T04CM04375

Parcel: 140383630


Addresses:

5870 E CHAUCERS DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
01/03/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/30/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/29/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSULATE CHANNELS
2) WIND BRACES REQUIRE 2 NAILS AT ENDS
3) HOLDOWN RIGHT SIDE OF SLIDER NOT NAILED TO TWO KING STUDS
4) OVER SPAN EAST WALL
5) STRAP ALL CORNERS NOT CABIN TIED
6) STOPPED INSPECTION
12/27/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*