Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/09/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* NOTE: CHECK AT INTERMEDIATE 1) FRIEZE BLOCK ALL BAYS FOR WEST SHEAR, AND 2 PANELS TO ROOF 2) KITCHEN SHEAR IS FROM WINDOW TO WINDOW, NEED ONE MORE PANEL . 3) TRUSS REPAIR OK 4) AT INTERMEDIATE HAVE DETAIL TRANSFER/SHEAR AT REAR BEDROOM |
|
| 01/24/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SUBMIT ASBUILT FOR APPROVAL GARAGE SW TRANSFER TO TRUSS (DIFFERENT THAN PLAN) 2) EPC CAPS BEAMS TO POSTS 3) 3 P.T. BEARINGS TRUSSES TO BE BEARING 4) S.W. PANEL MISSING GARAGE 5) MST STRAPS MISSING HOLDOWNS TO BEARING 6) STOPPED INSPECTION |
|
| 01/20/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GARAGE S.W. TRANSFER NOT PER PLAN SEE DETAILS 10/DT1 AND 14/DT1 2) BIRD BLOCK NAILING ON ROOF AND SHEAR TRANSFER GARAGE ROOF NAILING NOT PER PLAN |
|
| 01/18/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL PROTECT PLUMBING 2) NO TRUSS CALCS 3) SHEAR PANELS IN GARAGE NOT PER DETAIL 4) PROVIDE APPROVED REPAIR FOR DOIP TRUSS, SET BACKWARDS |
|
| 01/10/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STRAP PLUMBING EXTERIOR BOTTOM PLATES 2) STUDS SPLIT RSP45-REPLACE 3) SAME AS LOT 135 4) STOPPED INSPECTION |
|
| 01/03/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |