Permit: T04CM04374

Parcel: 140384010


Addresses:

5865 E CHAUCERS DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
02/09/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
NOTE: CHECK AT INTERMEDIATE
1) FRIEZE BLOCK ALL BAYS FOR WEST SHEAR, AND 2 PANELS TO ROOF
2) KITCHEN SHEAR IS FROM WINDOW TO WINDOW, NEED ONE MORE PANEL .
3) TRUSS REPAIR OK
4) AT INTERMEDIATE HAVE DETAIL TRANSFER/SHEAR AT REAR BEDROOM
01/24/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SUBMIT ASBUILT FOR APPROVAL GARAGE SW TRANSFER TO TRUSS (DIFFERENT THAN PLAN)
2) EPC CAPS BEAMS TO POSTS
3) 3 P.T. BEARINGS TRUSSES TO BE BEARING
4) S.W. PANEL MISSING GARAGE
5) MST STRAPS MISSING HOLDOWNS TO BEARING
6) STOPPED INSPECTION
01/20/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GARAGE S.W. TRANSFER NOT PER PLAN SEE DETAILS 10/DT1 AND 14/DT1
2) BIRD BLOCK NAILING ON ROOF AND SHEAR TRANSFER GARAGE ROOF NAILING NOT PER PLAN
01/18/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PROTECT PLUMBING
2) NO TRUSS CALCS
3) SHEAR PANELS IN GARAGE NOT PER DETAIL
4) PROVIDE APPROVED REPAIR FOR DOIP TRUSS, SET BACKWARDS
01/10/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STRAP PLUMBING EXTERIOR BOTTOM PLATES
2) STUDS SPLIT RSP45-REPLACE
3) SAME AS LOT 135
4) STOPPED INSPECTION
01/03/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*