Permit: T04CM04348

Parcel: 136312900


Addresses:

4806 S CHILEAN LP

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
01/28/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
EXTERIOR CLIP OK TRUSS CONNECTION WAS RESOLVED PREVIOUSLY TO DRY WALL INSTALLATION
12/09/2004 EXT METAL CLIPS/EXT SHEATHING Partial Approval 1) EXTERIOR CLIP OK TO COVER WALLS (EXT.)
2) SMALL GIRDER EG1 1876 POUNDS ON HANGER END, HUS 48 HOLD 1889 HANGER SPEC'D ON PLAN IS HUS26 ? HAVE ENGINEER CHECK
HANGER SIZE, CHECK AT INTERMEDIATE INSPECTION
12/07/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) FROM LAST INSPECTION CHANGE OUT (16 SINKERS) TO 16 COMMONS IN GIRDER TO GIRDER CONNECTION, BLK AND NAIL ALL ENDS OF ROOF DECK AND WHERE OSB TURNED PARALELL WITH TRUSSES
12/06/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) 1/8" ENDS AND EDGE NAILING REQUIRED ON ROOF. ROOF PANELS BLOCKED
2) NO PLANS/PERMIT ON SITE
12/03/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*/ 1) SEE ALL BLACK MARKS ON ROOF, NAILING AND BLOCKING MISSING THRU OUT
2) NAIL ALL FREIZE BLOCKS TO ROOF
3) USE CORRECT NAILS IN ALL HANGERS
4) EAST SIDE BOTH HEADERS, NOT SHOWN ON PLAN WITH GIRDER BEARING, ON THOSE TWO HEADERS, SIZES NOT ON PLANS
5) BROKEN STUD EAST WALL