Permit: T04CM04341

Parcel: 114480950

Inspection Status: Approved

Inspection History: STUCCO MESH

Permit Number - T04CM04341

Inspection Description - STUCCO MESH

Inspection Status - Approved

Date Description Inspector Results Comments
01/03/2005 STUCCO MESH Approved IVRS - Inspection :*
12/30/2004 STUCCO MESH Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/29/2004 STUCCO MESH Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REMOVE STAPLES BEHIND HOMERUNS
2) SEAL FLU CHASE AT 1ST TO 2ND FLOOR AND AT 2ND FLOOR CEILING
3) BANG PLATE CONDENSATE LINE
4) CORRECT HEADER AT BOTTOM OF STAIRS
5) SHIM HEADERS WHERE NEEDED
6) INSTALL LARGER NAILED FHA STRAPS AT KITCHEN EAST WALL
7) FILL TRANSFER AREAS OF 2ND FLOOR POSTS TO 1ST FLOOR POSTS
8) SEAL TUB HOLES
9) DRYER DUCT OUT OF WALL PLANE
12/28/2004 STUCCO MESH Not ready for Inspection IVRS - Inspection :*