Permit: T04CM04333

Parcel: 141175160

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T04CM04333

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/13/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/10/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NOT READY, CARPENTERS STILL WORKING
12/09/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) SHEAR TRANSFER, TOO MUCH AIR BETWEEN TOP PLATE AND SHEATHING, NAIL ENTIRE LENGTH OF WALL TO ROOF
2) A-4 TRUSS A BRACE. CONTINOUS BRACING FROM REAR OF HOUSE (A) TRUSSES UP TO A-1, A-2, OPOSITE SITE A4D
3) SHIM ALL 3PT TRUSSES
4) INSTALL BACKING FOR SIDE WALL FLASHING
5) NAIL ALL SHEAR PANELS TO ROOF
6) FOLLOW 10/DT1 FOR F A35 FOR SHEAR CONNECTIONS TO TRUSSES
12/08/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) CARPENTERS STILL WORKING
12/07/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*