Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T04CM04333

Parcel: 141175160

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/13/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/10/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NOT READY, CARPENTERS STILL WORKING
12/09/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) SHEAR TRANSFER, TOO MUCH AIR BETWEEN TOP PLATE AND SHEATHING, NAIL ENTIRE LENGTH OF WALL TO ROOF
2) A-4 TRUSS A BRACE. CONTINOUS BRACING FROM REAR OF HOUSE (A) TRUSSES UP TO A-1, A-2, OPOSITE SITE A4D
3) SHIM ALL 3PT TRUSSES
4) INSTALL BACKING FOR SIDE WALL FLASHING
5) NAIL ALL SHEAR PANELS TO ROOF
6) FOLLOW 10/DT1 FOR F A35 FOR SHEAR CONNECTIONS TO TRUSSES
12/08/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) CARPENTERS STILL WORKING
12/07/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*