Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM04316
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/07/2005 | FRAMING | Approved | IVRS - Inspection :* | |
01/05/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) BANG PLATES H20 SERVICE GARAGE 2) KITCHEN RANGE WIRE SECURE, AND BANG PLATE AT STUD 3) STRAP ACROSS DRYER DUCT 4) BEDROOM NEXT TO LAUNDRY, CIRCUIT NOT COMPLETE SAME BEDROOM, CLOSET LIGHT TO CLOOSE TO MECHANICAL DUCT CEILING 5) CLOSET FLANGE HALL BATH TOO CLOSE TO WALL 12" ROUGH IN 6) NORTH, PORCH MIDDLE POST, WAS INSTALLED AFTER SHEATHING INSPECTION HOW IS IT ATTACHED TO BEAM ? |
|
12/30/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) BANG PLATE H20 SERV. LEDGER, GARAGE 2) OVERSPAN STUD KITCHEN BACK SIDE OF TUB 3) SW1 SHEAR GARAGE WEST/NORTH WALLS BLOCK 4) STRAP ACCROSS DRYER DUCT 5) LOOSE OUTLET HALL FROM GARAGE 6) WASHER H20 LINES OUT OF WALL BEDROOM, SAME BEDROOM CLOSET LIGHT, DUCT 7) POCKET DOOR LOSSE, LOOSE PLATE SAME OPENING 8) TOILET FLANGE LESS THAN 12" FROM WALL 9) 04 DROP CEILING RENAIL 2 X 4'S SOUTH BEDROOM, BANG PLATE WIRE CLOSET 10) SECURE CRIPPLE FRONT WINDOW 11) FIRPLACE NOT INSTALLED CANNOT KILL A GAS LINE IN A WALL 12) SHOWER NOT INSTALLED, SHOWER RISER NOT PLUGGED 13) OVERSPAN MASTER CLOSET, AT DOOR BOTH SIDES 14) MIDDLE PORCH POST, STRAP TO BEAM |