Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM04316
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/22/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
11/19/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :*/ 1) NAIL OFF 4 X 8 SHEET ROOF DECK FRONT PORCH 2) TWO NAILS IN EACH WIND BRACE AT PLATES 3) MISSING SEVERAL WIND BRACES 4) INSTALL FRONT PORCH POST CHECK ? 5) BLOCK AT ALL SCUPPERS |