Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T04CM04315
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/18/2004 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
11/05/2004 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :*/ 1) HAVE PLAN APPROVED BY CITY, AT 3" TRUNK LINE PROBLEM | |
10/27/2004 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :*/ 1) CHANGE OUT 3" SECTION OF PIPE, 2" CLEANOUT FROM LAV TO CLEANOUT 2" TRUNK | |
10/25/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) PLAN CALLS FOR 1 1/4" H20 LINE, 1" INSTALLED 2) CLEANOUT MINIMUM SIZE FOR 3" WASTE LINE IS 2 1/2" YOU HAVE 2" 3) PLEASE LEAVE SAMPLE ON TAPERED BUSHING ON SITE |
|
10/20/2004 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :*/ 1) NEED A APPEAL FORM FOR IRC PLUMBING |